homeProductsThermometer>Bourdon tube filling type

Bourdon tube filling typeTFtypepdf Opened by the PDF form

  1. Remote measurement type that separates Instruction part and senser is used for the industrial use possible, and widely to use the expansion and the shrinkage of the sealing liquid (Or, gas).
  2. The scale interval can be legible, and be manufactured to the high temperature region from capitation compared with Vapor pressure type T.
  3. Because it is non-mercury, it is safe. It is possible to use it also for the food relation.

Example of order※When the mouse is put, the explanation is displayed.

TF B 100 × 0~100 L2 P・R1/2 d12×50 _

Please quote the sign from the following table.

Bourdon tube filling type

※When the temperature is selected, the material of Liquid part suits the measurement body to obtain the performance enough safely, and the temperature of using regularly becomes 30~60% of all scale ranges.

Type TF(Bourdon tube filling type)
External shape Connecting directly
movabilitytype(SignJ)
Connecting directly edge none type(SignA)
Remote measurement round edge type(SignB)
Remote measurement burial type(SignD)
Remote measurement with foot type(SignE)
Instruction part Size 100 75、100、150
(1)Temperature
span(℃)
-30~50,0~50,0~100,0~120,0~200,0~250,0~300,0~400,0~500
Accuracy ±2.0% FS
(2)PipeのLength:L(m) 3 <Specification>1~10 (Up to 20 by type).
Joint Shape Slide type(SignS) Union type(SignU)
Protection Tube assistant type(SignP)
flangetype(SignF) Throw type(SignX)
Connection
method
<Standard>R1/2
<Specification>R3/8、R3/4
JISflange
(Diameter)
Temperature
senser
(mm)
Diameter:d(mm) <Specification>8、10,12,14(It depends on type. )
(3)Special Protection Tube shape・Size
Length:L(mm) <Standard>100 <Specification>50、75、100、150、200、300、400、500
Main part
Material
senser
Protection Tube
(4)SUS
(5)Case ADC Black painting
Additiona
specification
Installation needle:Switch type(SignF7) Installation needleLabel type(SignF5)
(2)With Pipe sail correction(Sign10) With point of contact(SignM)
It depends on type.

□Remarks

  1. Please inquire when you need the temperature span of Others.
  2. The ambient temperature is perceived because it is enclosed with the part Pipe and Instruction part, it appears as a reading error margin, and there is what to need correcting. Please note the installation method of an abnormal temperature's not joining in the part Pipe and Instruction part.
  3. Please use Protection Tube as Size and Material that is sure to suit these when the measurement fluid pressures, is flow velocity, contains, and hardens and should do the Tube temperature part from the type thing and corrosion, etc. in Protection. (Please give the explanation of the thermometer of meter explanation to me in the reference. )Please inquire when you need Length of Others.
  4. Please inquire when you need OthersMaterial.
  5. Sealing uptype or SUSCase according to type can be produced. Please inquire.
Copyright (C) 2009 Takashimakeiki. All Rights Reserved.