homeProductsThermometer>Bimetal type T

Bimetal type TBS・BW・BG・BKtypepdf Opened by the PDF form

  1. The structure is easy and durability is abundant.
  2. It is possible to use it low-cost and easily.
  3. Please use it for the place where a lot of vibrations exist with the glycerin.

Example of order※When the mouse is put, the explanation is displayed.

BS T 100 × 0~100 P・R1/2 × 50 S2 _

Please quote the sign from the following table.

Bimetal type T

※When the temperature is selected, the material of Liquid part suits the measurement body to obtain the performance enough safely, and the temperature of using regularly becomes 30~60% of all scale ranges.

Type BS BW BG BK
Kind Standardtype Stainless steel
Sealing uptype
Glycerin
insertion
Small type
Instruction part Size 75,100,150 100 75,100 75,100 40 50 60,80
External shape Angletype
(SignT)
Straighttype
(SignS)
Inclinationtype
(SignR)
Movabilitytype
(SignJ)
Angletype(SignT)
Straighttype(SignS)
Angletype(SignT)
Temperature
span(℃)
-30~50,-10~50,0~50,0~100
0~120,0~150,0~200,0~250,0~300
0~50,0~100 Same to
Standardtype
Accuracy ±2.0% FS
Attaching
portion
Shape Slide type(SignS) <Standard>Union type(SignU)
(1)Protection Tube assistant type(SignP)
Flange type(SignF)
Fixation type
Connected screw <Standard>R1/2 R3/4 R1/4 R3/8 R1/2
Temperature
senser
(mm)
Diameter <Standard>8 (1)<Protection Tube>11
(1)<Protection TubeSUS材>12
<Specification>(1)Special Protection TubeのShape・Size
Length(ℓ) (4)50,75,100,150,200,300,400,500 <Standard>75
<Specification>
50,100
Main part
Material
senser
Protection Tube
<Standard>C3604.C1020 Ni plating(BWtype、And, SUS304 in case of 200℃ or more.)
<Specification>SUS304(SignS2)
Case ADCBlack painting SUS304・Cloth SUS
Additiona
specification
(2)Installation needle:Label type(SignF5) Switch type(SignF7)
(3)With contact point of contact(Only 75、100Ttype)(SignM)

□Remarks

  1. Please use Protection Tube as Size and Material that suits these when the measurement fluid pressures, is flow velocity, contains, and hardens and should do senser from the type thing and corrosion, etc. in Protection. Please see here of the explanation about the matter concerning these.
  2. Please see "Installation needle" for details of Installation needle.
  3. The contact capacity of With contact point of contact is AC100V-0.4A
  4. Long Protection Tube of 150milli or more must use made of Stainless steel.
Copyright (C) 2009 Takashimakeiki. All Rights Reserved.